|
Microstim gmbh
2-channel portable electrical stimulator 2 Channel Portable Electrical Stimulator, supplied by Microstim gmbh, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/functional+electrical+stimulation/pmc04616090-71-31-35 Average 90 stars, based on 1 article reviews
2-channel portable electrical stimulator - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
ADInstruments
2 channel stimulus generator 2 Channel Stimulus Generator, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/4+Channel+Stimulus+Generator/pm31134192-80-8-6 Average 93 stars, based on 1 article reviews
2 channel stimulus generator - by Bioz Stars,
2026-11
93/100 stars
|
Buy from Supplier |
|
Triangle Biosystems
stimulation system tbsi s-series ![]() Stimulation System Tbsi S Series, supplied by Triangle Biosystems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/stimulation+system+tbsi+s+series/pmc03809915-386-8-10 Average 90 stars, based on 1 article reviews
stimulation system tbsi s-series - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Thermo Fisher
gene exp loc103694380 rn01525859 g1 ![]() Gene Exp Loc103694380 Rn01525859 G1, supplied by Thermo Fisher, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/Gene+Exp%2E+LOC103694380%2C+Rn01525859_g1/10__55730_slash_1300___0152__2583-65-7--1 Average 99 stars, based on 1 article reviews
gene exp loc103694380 rn01525859 g1 - by Bioz Stars,
2026-11
99/100 stars
|
Buy from Supplier |
|
Mcs GmbH
2-channel general-purpose stimulus generator #stg 4002 ![]() 2 Channel General Purpose Stimulus Generator #Stg 4002, supplied by Mcs GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/stimulus+generator+stg+2004/pm27875989-68-1-10 Average 90 stars, based on 1 article reviews
2-channel general-purpose stimulus generator #stg 4002 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
PlasticsOne inc
2-channel twisted electrode with a 0.3-mm diameter ![]() 2 Channel Twisted Electrode With A 0.3 Mm Diameter, supplied by PlasticsOne inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/twisted+bipolar+stimulating+electrode+plastics+one/pmc06050411-31-1-10 Average 90 stars, based on 1 article reviews
2-channel twisted electrode with a 0.3-mm diameter - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Mcs GmbH
2-channel general-purpose stimulus generator ![]() 2 Channel General Purpose Stimulus Generator, supplied by Mcs GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/2+channel+general+purpose+stimulus+generator/pmc05120515-76-1-10 Average 90 stars, based on 1 article reviews
2-channel general-purpose stimulus generator - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
ALA Scientific Instruments
usb multifunction 2 channel arbitrary waveform generator digistim-2 ![]() Usb Multifunction 2 Channel Arbitrary Waveform Generator Digistim 2, supplied by ALA Scientific Instruments, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/usb+multifunction+2+channel+arbitrary+waveform+generator+digistim+2/pm38993080-60-19-27 Average 90 stars, based on 1 article reviews
usb multifunction 2 channel arbitrary waveform generator digistim-2 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
VIASYS HealthCare Inc
2-channel teca synergy system ![]() 2 Channel Teca Synergy System, supplied by VIASYS HealthCare Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/teca+synergy+n2+system/10__1590_slash_0103___8478cr20141716-54-8-12 Average 90 stars, based on 1 article reviews
2-channel teca synergy system - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
PlasticsOne inc
stimulating electrode ![]() Stimulating Electrode, supplied by PlasticsOne inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/2+channel+commutator/pmc06338792-246-47-51 Average 90 stars, based on 1 article reviews
stimulating electrode - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
|
Soterix Medical
soterix medical 2 channel stimulator ![]() Soterix Medical 2 Channel Stimulator, supplied by Soterix Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/2+channel+medical+soterix+stimulator/pmc12462536-97-32-32 Average 86 stars, based on 1 article reviews
soterix medical 2 channel stimulator - by Bioz Stars,
2026-11
86/100 stars
|
Buy from Supplier |
|
SystemTechnik GmbH
2-channel stimulus generator ust/040 ![]() 2 Channel Stimulus Generator Ust/040, supplied by SystemTechnik GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/2-channel+stimulus+generator+ust/2+kanaligen+reizgeber+ust+040/pm15219315-105-5-9 Average 90 stars, based on 1 article reviews
2-channel stimulus generator ust/040 - by Bioz Stars,
2026-11
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of neuroscience methods
Article Title: An inexpensive, charge-balanced rodent deep brain stimulation device: a step-by-step guide to its procurement and construction
doi: 10.1016/j.jneumeth.2013.08.003
Figure Lengend Snippet: Design A is designed to be plugged directly into a socket (363 plug, Plastics 1) cemented onto the subjects skull, it has no on/off switch. Switching the device on/off is achieved by shorting the power line switching the device on. Two pins connected by a short wire must be inserted into the contact housing during implantation (pins 1 and 2). The contacts of the stimulating electrodes (E363/6/SP, Plastics 1, pins 5 and 6) and the contacts for the current return path (“ground”) must be inserted into their respective positions in the contact housing (pins 3 and 4). Two contact positions (pins 3 and 4) connect with the battery ground for those using bipolar electrodes (E363/6/SP-2TW, Plastics 1). Only 1 (either will do) of these is necessary for monopolar stimulation referenced to a screw electrode (E363/20/SP, Plastics 1) implanted in the skull. Design B is designed to be carried on a rodent jacket and includes a dedicated on/off switch. Thus fewer connections are required in the electrode pedestal. When ordering the cable the connection diagram must also be sent to Plastics 1 to guarantee the correct connections.
Article Snippet: 10g) while much heavier than a similar commercial
Techniques: Battery
Journal: Journal of neuroscience methods
Article Title: An inexpensive, charge-balanced rodent deep brain stimulation device: a step-by-step guide to its procurement and construction
doi: 10.1016/j.jneumeth.2013.08.003
Figure Lengend Snippet: This PCB has a footprint identical the device presented in figure 2. The circuit switches on/off via a miniature slide switch rather than through shorting contacts in the power trace. Thus care must be taken not to encapsulate the switch. (A) 3 channel 363-SL/3 cable (Plastics 1). (B) Device output: the white termination must be connected to ground. The other terminations are the stimulation channels. (C) The output solder pads are nested between the battery connectors. (D) The complete (unencapsulated) device. (E) Devices are prepared for attachment to the small rodent jackets by sticking the hooked side of adhesive hook-and-loop tape to the topmost surface of the device. The looped side of the hook-and-loop tape was stuck to the underside of the device to cushion the battery housings which would otherwise have been adjacent to the animals back. The devices then stick easily to the hook-and-loop material stitched into the rodent jacket. A 10 cent (€) coin is included for scale. Inset: switch positions.
Article Snippet: 10g) while much heavier than a similar commercial
Techniques: Battery, Adhesive
Journal: Experimental Neurobiology
Article Title: Desynchronization of Theta Oscillations in Prefrontal Cortex during Self-stimulation of the Medial Forebrain Bundles in Mice
doi: 10.5607/en.2018.27.3.181
Figure Lengend Snippet: Experimental setup and histological verification of the stimulation site. (A) Experimental setup for ICSS. A mouse was positioned in a custom-made stimulation chamber with free access to a wheel. When the mouse turned the wheel by 1/4 of a rotation, a trigger signal from a rotation sensor was sent to both a pulse stimulator and an analog-to-digital (A/D) converter. The pulse stimulator gave the electrical stimulation to the MFB following a protocol arranged in the stimulator. Prefrontal EEG and hippocampal LFP data were acquired by an analog amplifier, digitalized at 500 Hz and recorded by a computer. (B) Histological verification of the tip of the stimulating electrode. CM, central medial thalamic nucleus; ic, internal capsule; mt, mammillothalamic tract; mfb, medial forebrain bundle; 3v, third ventricle.
Article Snippet: A
Techniques: